Network Platforms - Liquid Maintenance scheduled on the 22 June 2025 – Maintenance details

Liquid Maintenance scheduled on the 22 June 2025

Completed
Scheduled for June 22, 2025 at 5:00 AM – 4:00 PM

Affects

National Long Distance

Under maintenance from 5:00 AM to 4:00 PM

CT1 - JB1 - Liquid

Under maintenance from 5:00 AM to 4:00 PM

Updates
  • Completed
    June 22, 2025 at 4:00 PM
    Completed
    June 22, 2025 at 4:00 PM
    Maintenance has completed successfully
  • In progress
    June 22, 2025 at 5:00 AM
    In progress
    June 22, 2025 at 5:00 AM
    Maintenance is now in progress
  • Planned
    June 22, 2025 at 5:00 AM
    Planned
    June 22, 2025 at 5:00 AM

    Dear Customer,

     

    Please take note of a Liquid Emergency Change Scheduled ALONG ZUURFONTEIN  NEAR THE BRIDGE AT THE GARAGE on the 22nd June 2025 from 07:00 - 18:00. We need to remake the joint that is in a bad state, causing high losses along Zuurfontein.

     

    IMPACT: Services Highlighted in red will be down for a maximum duration of 10Hrs, other services will experience an intermittent 50ms switching hit.

     

     

    Affected Services:

    CT1 - JB1 - Liquid

     

     

    Reason For Change

     

    To remake the joint that is in a bad state, causing high losses along Zuurfontein.

     

     

    Implementation Plan

     

    1.            New cable already installed.

    2.            Cables will be prepared after into new fibre joints.

    3.            The newly installed cable will be tested for quality use.

    4.            Cut the old cable and prepare it into the new joint.

    5.            Splice the cable as per service priority.

    6.            Continuously confirming with both IP NOC for service restoration

    7.            Splice the rest of the fibres once all workers are through.

    8.            Final confirmation with both NOC on completion.

     

    Rollback Plan:

     

    System(s) will be cut on new cable as per priority and service affecting.

    OSP will continuously confirm during and after the cut over with both IP and SDH NOC.

    Should there be any system which is still down after the planned work execution, then it will be treated as fault.

    Fibre fault diagnose process will kick in to restore the affected services. End to end test will be done to check fibre conditions.

    The test will be performed between the applicable POP and the jointing site. OSP FST will ensure that all links are up before parting site.