Network Platforms - Notice history

Notice history

Jul 2025

Liquid NLD Maintenance CPT-JHB - 12 July 08:00 to 15:00
Scheduled for July 12, 2025 at 6:00 AM – 1:00 PM about 7 hours
  • Planned
    July 12, 2025 at 6:00 AM
    Planned
    July 12, 2025 at 6:00 AM

    Dear Customer,

     

    Please take note of a Liquid Planned Change scheduled between Zuurbekom and Potchefstroom on the 12th July 2025 from 08:00 to 15:00. We need to remake damaged Liquid Joint on N12 Foghville Between Zuurbekom and Potchefstroom. The fibre has high losses.

     

    IMPACT: Services will experience an intermittent 50ms switching hit. 

     

    Affected Service(s):

    NLD CT1- JB1 - Liquid

     

    Reason for Change:

     

    To remake damaged Liquid Joint on N12 Foghville Between Zuurbekom and Potchefstroom. The fibre has high losses.

     

     

    Implementation Plan

     

    Cut into existing Splice closure: Tenio  

    If one of the adjacent manholes contains an existing splice, the following minimum procedure needs to be followed:  

     

    ·                  Confirm the working fibres for each cable. 

    ·                  Uncoil the cable slack from the manhole and remove the closure. 

    ·                  Mount the closure in the splicing vehicle and open the closure. 

    ·                  Ensure that the GRP of both cables are properly secured.  

    ·                  Remove the heat shrink seal as follows: 

    o        Use a sharp knife and score (partially cut – about two thirds) the heat shrink seal longitudinally 

    o        Heat the seal with a gas torch – the heat shrink will split along the score line. 

    o        Remove the heat shrink completely with pair pliers while it is hot. 

    ·                  Prepare the end of the new cable – remember to balance the slack to the existing cable. 

    ·                  Install the cable also through the Oval port and secure the GPR. 

    ·                  Cut the fibres in the tubes that contain only spare fires and remove the tube and fibres of the faulty cable side from the trays.  

    ·                  Splice the same tubes from the new cable onto these fibres. 

    ·                  When all the tubes that contain spare fibres are spliced, test all the spare fibres from both adjacent PoP’s and create a bi-directional trace to confirm that all splice losses meet the 0.15dB loss requirement. If not, re-splice until it is met. 

    ·                  If all splice losses are within specification, transfer the working circuits at both POP’s to a pair(s) of the new spare fibres. Please assure that the necessary permissions are obtained prior to this.  

    ·                  Now at the splice, cut the remaining fibres and splice through on to the new cable. 

    ·                  Do again bi-directional OTDR tests to confirm that these splice losses are also within the specification. 

    ·                  Remove old cable completely from the closure. 

    ·                  Re-seal the oval spigot by using a FOSC OVAL SPIGOT WRAP AROUND SHRINK SEAL KIT. 

    ·                  Fit closure and manage cable slack as per normal. 

    Cut into existing cable: Will be checked. 

    ·                  Remove cable slack from the manhole. 

    ·                  Measure 10m slack from the healthy cable entry into the manhole. 

    ·                  From this point remove 3m of cable sheath. 

    ·                  Open the oval port of a new Closure and slide the new heat shrink over the looped cable end. 

    ·                  Push the looped cable end through the oval port. Apply caution not to kink or bend tubes to short as there is still fibre that carries traffic. Secure the GRP on both sides. 

    ·                  Put the traffic carrying tube one side and cut the tubes with the spare fibres. 

    ·                  Cut the fibres in the tubes that contain only spare fires and remove the tube and fibres of the faulty cable side. 

    ·                  Splice the same tubes from the new cable onto these fibres. 

    ·                  When all the tubes that contain spare fibres are spliced, test all the spare fibres from both adjacent PoP’s and create a bi-directional trace to confirm that all splice losses meet the 0.15dB loss requirement. If not, re-splice until it is met. 

    ·                  If all splice losses are within specification, transfer the working circuits at both POP’s to a pair(s) of the new spare fibres. Please assure that the necessary permissions are obtained prior to this.  

    ·                  Now at the splice, cut the remaining fibres and splice through on to the new cable. 

    ·                  Do again bi-directional OTDR tests to confirm that these splice losses are also within the specification. 

    ·                  Remove old cable completely from the closure. 

    ·                  Close oval spigot with heat shrink seal as per normal. 

    ·                  Fit closure and manage cable slack as per normal. 

     

    3.                Removal of Faulty Cable 

    Recover of faulty Fibre cable from ducts preferable by means of blowing. 

    4.                Repair New Spare Duct 

    Repair the new spare duct by following the same procedure as in clause 4.1.  

    Confirm integrity of the repair with a DIT test. 

     

    5.                Closing the Excavation 

    Remove the canvas from underneath the ducts. Ensure that all stones are removed from the excavation. Ensure that the area underneath the ducts is levelled with bedding material. 

    Ensure the ducts are straight with the correct duct spacing. Fill the area to 100mm above the ducts with padding material and compact lightly. 

    Fill the rest of the excavation in layers of 150 – 200mm and compact each layer. 

    Reinstate at NGL to as before. 

     

    6.                 Final Testing 

    After all splices are completed and all slack managed and store and closures are fitted and excavations is filled, repeat bi-directional OTDR test on all fibres to confirm compliance of the splice losses to specification. 

     

    Repeat DIT test to confirm that ducts were not damaged during compaction.

     

     

    Roll Back Plan

     

    If the planned cut over fails the splicing team will splice the fibres back to its original state, 2 pairs of fibre are currently splice through on tube no 1 if cut over fail the fibres will be spliced back to their original state.

Jun 2025

Monitoring Server down
  • Resolved
    Resolved

    Good day,


    Please note that our monitoring server infrastructure has been restored. The temporal outage did not affect any client services.


    You may have received notifications that can be ignored.


    If you are experiencing any issues, please log a ticket via support@networkplatforms.co.za


    Kind regards,

    Network Platforms

  • Investigating
    Investigating

    Good day

    Please note that our monitoring infrastructure is currently down. Our engineers are currently investigating. This is not affecting any services.


    You may receive notifications when the infrastructure is getting restored, these can be ignored.


    If you are experiencing any issues, please log a ticket via support@networkplatforms.co.za


    Kind regards,

    Network Platforms

JB1-DB1 Openserve East NLD
  • Resolved
    Resolved

    Good day,

    We’re pleased to inform you that the Openserve East NLD between JB1 and DB1 is now fully operational.

    The fault has been resolved by the provider. We will provide a Root Cause Analysis (RFO) on request if we have received one from the provider.

    If you're still encountering problems, please don't hesitate to log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms Team

  • Investigating
    Investigating

    Good day,

    We're currently experiencing an outage on the Openserve East NLD connection between JB1 and DB1.

    This issue has been escalated to the provider for further investigation.

    Please note, clients with a protected service should be unaffected by this incident.

    If you're on a protected service and still encountering issues, please log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms

Liquid Maintenance scheduled on the 22 June 2025
  • Completed
    June 22, 2025 at 4:00 PM
    Completed
    June 22, 2025 at 4:00 PM
    Maintenance has completed successfully
  • In progress
    June 22, 2025 at 5:00 AM
    In progress
    June 22, 2025 at 5:00 AM
    Maintenance is now in progress
  • Planned
    June 22, 2025 at 5:00 AM
    Planned
    June 22, 2025 at 5:00 AM

    Dear Customer,

     

    Please take note of a Liquid Emergency Change Scheduled ALONG ZUURFONTEIN  NEAR THE BRIDGE AT THE GARAGE on the 22nd June 2025 from 07:00 - 18:00. We need to remake the joint that is in a bad state, causing high losses along Zuurfontein.

     

    IMPACT: Services Highlighted in red will be down for a maximum duration of 10Hrs, other services will experience an intermittent 50ms switching hit.

     

     

    Affected Services:

    CT1 - JB1 - Liquid

     

     

    Reason For Change

     

    To remake the joint that is in a bad state, causing high losses along Zuurfontein.

     

     

    Implementation Plan

     

    1.            New cable already installed.

    2.            Cables will be prepared after into new fibre joints.

    3.            The newly installed cable will be tested for quality use.

    4.            Cut the old cable and prepare it into the new joint.

    5.            Splice the cable as per service priority.

    6.            Continuously confirming with both IP NOC for service restoration

    7.            Splice the rest of the fibres once all workers are through.

    8.            Final confirmation with both NOC on completion.

     

    Rollback Plan:

     

    System(s) will be cut on new cable as per priority and service affecting.

    OSP will continuously confirm during and after the cut over with both IP and SDH NOC.

    Should there be any system which is still down after the planned work execution, then it will be treated as fault.

    Fibre fault diagnose process will kick in to restore the affected services. End to end test will be done to check fibre conditions.

    The test will be performed between the applicable POP and the jointing site. OSP FST will ensure that all links are up before parting site.

JB1-DB1 Openserve West NLD
  • Resolved
    Resolved

    Good day,

    We’re pleased to inform you that the Openserve West NLD between JB1 and DB1 is now fully operational.

    The fault has been resolved by the provider. We will provide a Root Cause Analysis (RFO) on request if we have received one from the provider.

    If you're still encountering problems, please don't hesitate to log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms Team

  • Investigating
    Investigating

    Good day,

    We're currently experiencing an outage on the Openserve West NLD connection between JB1 and DB1.

    This issue has been escalated to the provider for further investigation.

    Please note, clients with a protected service should be unaffected by this incident.

    If you're on a protected service and still encountering issues, please log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms

May 2025

JB1-CT1 Fibreco NLD
  • Resolved
    Resolved

    Good day,

    We’re pleased to inform you that the Fibreco NLD between JB1 and CT1 is now fully operational.

    The fault has been resolved by the provider. We will provide a Root Cause Analysis (RFO) on request if we have received one from the provider.

    If you're still encountering problems, please don't hesitate to log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms Team

  • Identified
    Identified

    Update: Break is between Parys and Kroonstad

    Seacom will have technicians at Parys in 30 minutes and Kroonstad in 60 minutes to start localising the issue.

  • Investigating
    Investigating

    Good day,

    We're currently experiencing an outage on the Fibreco NLD connection between JB1 and CT1.

    This issue has been escalated to the provider for further investigation.

    Please note, clients with a protected service should be unaffected by this incident.

    If you're on a protected service and still encountering issues, please log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms

JB1-CT1 Openserve NLD
  • Resolved
    Resolved

    Good day,

    We’re pleased to inform you that the Openserve NLD between JB1 and CT1 is now fully operational.

    The fault has been resolved by the provider. We will provide a Root Cause Analysis (RFO) on request if we have received one from the provider.

    If you're still encountering problems, please don't hesitate to log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms Team

  • Investigating
    Investigating

    Good day,

    We're currently experiencing an outage on the Openserve NLD connection between JB1 and CT1.

    This issue has been escalated to the provider for further investigation.

    Please note, clients with a protected service should be unaffected by this incident.

    If you're on a protected service and still encountering issues, please log a ticket at support@networkplatforms.co.za.

    Kind regards,

    Network Platforms